Research Article

The Optimal Hydraulic Design of Centrifugal Impeller Using Genetic Algorithm with BVF

Table 4

Grid independence analysis.

Cell number625173841281112929913581541543701

Head coefficient0.8360.8430.8490.8530.856
Efficiency0.75730.76980.77430.77630.7780