Research Article

Experimental Aspects in the Vibration-Based Condition Monitoring of Large Hydrogenerators

Table 3

Temperatures in the pads of upper journal bearing of a LHG.

Operating conditionPad number 4Pad number 12
L. EdgeT. EdgeL. EdgeT. Edge
[MW][°C][°C][°C][°C]

78.5035.337.835.939.5
92.3043.348.445.251.5
92.360044.848.147.153.7
92.370047.049.749.256.0
92.355.258.657.364.6

the last measurement with 700 MW, a reduction of 10% in the bearing cooling capacity was created artificially by adequately reducing the water flow in the heat exchangers.