Research Article

Fourier Spectroscopy: A Bayesian Way

Figure 7

Odds for maxima of dependent on spectral increment . The maximum at = 1/2 GHz is used as a reference (unity odd). For = 1/3 GHz and 1/4 GHz, the maximising parameter set (see Table 1) for = 1/2 GHz is used to evaluate the associated odds. The global maximum of is obtained for very small spectral increments.