Research Article

Multi-Sensor-Fusion Approach for a Data-Science-Oriented Preventive Health Management System: Concept and Development of a Decentralized Data Collection Approach for Heterogeneous Data Sources

Table 1

Battery usage of mDCS (MobMedApp) for different configuration cases over eight-hour measurements using the smart phone Samsung Galaxy S8 (mAh—milli ampere hour).

Configuration case descriptionBattery usage of MobMedAppBattery usage of mDCS

(1) MobMedApp in idle-mode1.7 ± 0.4% (approx. 51 mAh)2.8 ± 0.3% (approx. 83 mAh)
(2) MobMedApp using Fitbit-provider cloud and p2-Health-Cloud2.0 ± 0.1% (approx. 60 mAh)3.8 ± 0.3% (approx. 113 mAh)
(3) MobMedApp using Equivital™ EQ01 (with continuous data transmission) and p2-Health-Cloud15.9 ± 0.7% (approx. 477 mAh)16.7 ± 1.0% (approx. 500 mAh)
(4) MobMedApp using Fitbit-provider cloud, Equivital™ EQ01 (with continuous data transmission) and p2-Health-Cloud18.9 ± 0.7% (approx. 565 mAh)19.8 ± 0.9% (approx. 595 mAh)