Research Article

Rehabilitation of Shear-Damaged Reinforced Concrete Beams Using Self-Compacting Concrete Jacketing

Table 4

Mean compressive and splitting tensile strength of SCC.

Jacket of beam:B1-JB2-JB3-JB4-JB5-J

Compressive strength (MPa)43.942.840.540.039.8
Tensile splitting strength (MPa)3.543.723.473.253.32