Research Article

Numerical Implementations for 2D Lid-Driven Cavity Flow in Stream Function Formulation

Table 6

Comparison of the three schemes on the primary vortex at : minimum of the stream function and location.

Reference Grid

Explicit 0.540 0.560
Operator 0.520 0.580
Internal 0.540 0.560
Explicit 0.530 0.560
Operator 0.530 0.560
Internal 0.530 0.560
Ref. [14] 160 0.5308 0.5652
Ref. [4] 0.53125 0.5625
Ref. [4] 0.53125 0.56543
Ref. [1] 0.5316 0.5660
Ref. [15] 0.5250 0.5750