Research Article

Heating and Efficiency Comparison of a Fischer-Tropsch (FT) Fuel, JP-8+100, and Blends in a Three-Cup Combustor Sector

Table 2

Average unwrapped liner temperature differencesa,b: FT fuel and 50 : 50 blend with respect to JP-8+100 (°F) [ΔT (°F) = 1.8ΔT (K)].

F/A = 0.010F/A = 0.015F/A = 0.020F/A = 0.025

Inlet pressure JP-8FT50 : 50JP-8FT50 : 50JP-8FT50 : 50JP-8FT50 : 50

75 psia
(0.52 MPa)
3%0−4−501−60−15−110−12−16
4%0−200−2−20−9−70−12−8
5%0−3−20−1−20−2−30−31

125 psia
(0.86 MPa)
3%0−6−60−20−150−28−18
4%01−10−6−60−29−16
5%0620−10−50−23−11

175 psia
(1.21 MPa)
3%0720−25−60−39−18
4%0100−13−100−22−14
5%0210−11−70−26−17

225 psia
(1.55 MPa)
3%012120−20−130−46−16
4%018170−9−40−31−14
5%0630−910−39−14

a (P,T)inlet = [75 psia (0.52 MPa), 500°F  (533 K)], [125 psia (0.86 MPa), 625°F (603 K)],
[175 psia (1.21 MPa), 725°F (658 K)], and [225 psia (1.55 MPa), 790°F (694 K)].
bΔT < 0 implies cooler liner temperature.