Results of robustness.
| Parameter | CLA (% RSD) | PCM (% RSD) | Inference |
| Flow rate (±0.2 mL/min) | | | | 0.8 mL/min | 0.31 | 0.12 | RSD % was found to be <2 | 1.2 mL/min | 0.59 | 0.25 | Wavelength (±2 nm) | | | 203 nm | 0.42 | 0.23 | 207 nm | 0.30 | 0.25 |
|
|