Clinical Study

Comparison of Functional Outcomes of Tibial Plateau Fractures Treated with Nonlocking and Locking Plate Fixations: A Nonrandomized Clinical Trial

Table 2

Postoperative step-off and widening status by fracture systems.

Type of fracture Locking methodsNonlocking methods
Step-off >2 mmWidening >2 mmStep-off >2 mmWidening >2 mm

Schatzker system
 Grade I0 (0.0)*0 (0.0)*0 (0.0)0 (0.0)
 Grade II2 (22.2)0 (0.0)5 (45.5)2 (18.2)
 Grade III1 (100)1 (100)1 (50.0)0 (0.0)
 Grade IV0 (0.0)0 (0.0)0 (0.0)1 (100)
 Grade V1 (33.3)0 (0.0)0 (0.0)1 (100)
 Grade VI0 (0.0)0 (0.0)1 (25.0)0 (0.0)
value0.1910.6820.6840.748
AO system
 B10 (0.0)0 (0.0)0 (0.0)0 (0.0)
 B21 (16.7)0 (0.0) 2 (20.0)1 (10.0)
 B31 (20.0)0 (0.0)5 (83.3)2 (3.3)
 C11 (25.0)0 (0.0)0 (0.0)1 (100)
 C21 (25.0)1 (25.0)0 (0.0)0 (0.0)
 C30 (0.0)0 (0.0)0 (0.0)0 (0.0)
value0.9810.3780.6670.164

Data are presented as number (%).
Analyses were performed using the chi-square test or Fisher's exact test (all values were more than 0.05).