Table 1
Spectral and statistical data for the determination of SEG.
| Parameters | Method A | Method B |
| (nm) | 629 | 539 | Beer’s law limits (μg/mL) | 10.00–85.00 | 20.00–120.00 | Molar absorptivity (L mol−1 cm−1) | 0.98 × 104 | 0.94 × 104 | Sandell’s sensitivity (μg cm−2) | 3.33 × 10−2 | 1.98 × 10−2 | Limit of detection* (μg mL−1) | 0.8059 | 0.4347 | Limit of quantification* (μg mL−1) | 2.4423 | 1.3173 | Regression equation** | | | Slope (b) | 0.0124 | 0.0046 | Intercept (a) | 0.1428 | 0.0047 | Correlation coefficient (r) | 0.9924 | 0.9987 |
|
|
Limit of detection calculated according to ICH guidelines.
**
Y is the absorbance and X is the concentration in μg mL−1.
|