Research Article

Exhaled Eicosanoids following Bronchial Aspirin Challenge in Asthma Patients with and without Aspirin Hypersensitivity: The Pilot Study

Table 3

Eicosanoids values at baseline and following aspirin challenge in AIA and ATA patients. Results of eicosanoids were recalculated as picograms per milliliter (pg/mL).

AIA ( )ATA ( ) (ANOVA)
BaselineAfter the challengeBaselineAfter the challengeAfter the challenge

PGD2 0.35
(pg/mL)1.011.211.641.53
GC/MS

PGD2 0.05
(pg/mL)1.391.091.481.45
HPLC

9α11βPGF2 0.59
(pg/mL)0.360.340.290.28
GC/MS

PGF2α 0.82
(pg/mL)0.280.270.300.23
GC/MS

6-keto-PGF1α 0.53
(pg/mL)7.177.227.487.46
GC/MS

6-keto-PGF1α 0.60
(pg/mL)7.266.967.407.65
HPLC/MS/MS

11-dehydro TXB2 * * 0.18
(pg/mL)5.746.176.816.62
GC/MS

11-dehydro TXB2 * * 0.03*
(pg/mL)5.496.036.636.18
HPLC/MS/MS

LTC4 * 0.01*
(pg/mL)2.302.022.461.06
HPLC/MS/MS

LTD4 0.16
(pg/mL)0.690.651.340.95
HPLC/MS/MS

LTE4 * * 0.04*
(pg/mL)1.832.331.932.45
HPLC/MS/MS

Total cysLTs 0.24
(pg/mL)5.976.017.244.90
HPLC/MS/MS

LTB4 * 0.02*
(pg/mL)29.6616.9927.7315.35
HPLC/MS/MS

5 HETE 0.79
(pg/mL)2.943.412.291.67
HPLC/MS/MS

12 HETE * 0.02*
(pg/mL)4.052.823.101.93
HPLC/MS/MS

15 HETE * * 0.30
(pg/mL)5.964.772.952.39
HPLC/MS/MS

EXC4 0.74
(pg/mL)0.790.590.800.61
HPLC/MS/MS

EXD4 0.909
(pg/mL)0.730.621.060.74
HPLC/MS/MS

EXE4 0.07
(pg/mL)2.151.051.591.35
HPLC/MS/MS

8-iso-PGF2α * * 0.92
(pg/mL)0.200.210.350.34
GC/MS

Median (25% and 75% percentiles).
AIA: aspirin-induced asthma. ATA: aspirin-tolerant asthma.
* -values < 0.05; AIA versus ATA at baseline or after the challenge.
-values:
* AIA versus ATA at baseline.
*baseline versus challenge in AIA.