Research Article
Hydraulic Transients Induced by Pigging Operation in Pipeline with a Long Slope
Table 1
Summary of basic parameters for field operations.
| Parameters | Values |
| The length of pipeline | 6.93 Km | Pipe size | Φ1219 × 18.4 mm | The maximum elevation difference | 178.5 m | Wall equivalent roughness | 0.01 mm | Mass of pig | 700.0 kg | Frictional resistance between pig and pipe wall | 0.03 MPa | Static friction resistance between pig and pipe wall | 0.04 MPa | Type of compressor | XHP1070 | Rated operating pressure | 2.2 MPa | Air displacement | 30.0 Nm3/min |
|
|