Research Article

Cylinder Position Servo Control Based on Fuzzy PID

Table 5

Control errors of cylinder position (mm).

InitialTargetAERE

1002500.24410.20%
1003000.200.07%
1003500.24410.09%

AE represents absolute error and RE denotes relative error.