Research Article

Handing Tolerance Problem in Fault Diagnosis of Linear-Analogue Circuits with Accurate Statistics Approach

Table 6

The FSV range estimated through normal quantile distribution in the circuit of Figure 7.

Diagnosis?

(0.64, 0.86) (0.72, 1.06) (0.74, 1.11) (0.71, 1.34) (0.76, 1.46) Y
(−0.84, −0.56) (−0.90, −0.54) (−0.93, −0.61) (−1.37, −0.55) (−1.33, −0.74) Y
(−0.47, −0.16) (−1.03, −0.23) (−0.10, −0.24) (0.20, 0.95) (0.26, 1.06) Y
(0.14, 0.60) (1.63, 4.00) (1.68, 4.31) (1.61, 4.32) (2.12, 4.95) Y
(−1.59, −0.25) (−1.61, −0.37) (−2.76, −1.87) (−3.55, −2.06) (−4.08, −2.06) Y
(−3.03, −1.39) (−3.81, −1.58) (−0.79, −0.58) (−1.17, −0.49) (2.99, 4.67) Y