Research Article
Modeling and Parameter Analysis of the OC3-Hywind Floating Wind Turbine with a Tuned Mass Damper in Nacelle
Table 5
Percentage of load reduction with different TMD tuning results compared with baseline.
| Case | Evaluation index | Den1 | Den2 | | |
| 10 m/s | DEL TwrBsMyt | 6.35 | 0.66 | 0.52 | 6.00 | DEL TwrBsMxt | 32.18 | 14.2 | 11.44 | 28.37 | DEL RootMyc1 | 1.07 | −0.18 | 0.10 | 0.85 | DEL Anch1Ten | 0.93 | 3.01 | 1.21 | 0.93 | 95th TwrBsMyt | −2.00 | −4.04 | −3.89 | −2.00 | 95th TwrBsMxt | 6.01 | 2.7 | 2.55 | 5.06 | 95th PtfmPitch | −2.08 | −1.96 | −2.08 | −2.08 | 95th PtfmRoll | −1.67 | 0.21 | 0.13 | −1.67 |
| 18 m/s | DEL TwrBsMyt | 3.61 | 7.77 | 8.78 | 3.35 | DEL TwrBsMxt | 25.55 | 0.98 | −3.94 | 21.24 | DEL RootMyc1 | 1.07 | 4.99 | 5.93 | 1.14 | DEL Anch1Ten | 1.15 | 0.32 | 0.32 | 1.14 | 95th TwrBsMyt | −3.15 | 5.02 | 6.48 | −3.25 | 95th TwrBsMxt | 7.90 | 4.70 | 1.69 | 7.10 | 95th PtfmPitch | −1.05 | 10.66 | 12.43 | −1.04 | 95th PtfmRoll | 6.55 | 15.54 | 14.32 | 6.58 | RMS GenPwr | −5.46 | 21.09 | 29.22 | −5.41 |
| 37 m/s | DEL TwrBsMyt | 1.47 | −19.95 | −16.25 | 1.22 | DEL TwrBsMxt | 0.14 | 0.51 | 0.42 | 0.18 | DEL RootMyc1 | 1.80 | −45.71 | −28.34 | 2.03 | DEL Anch1Ten | 1.33 | 1.83 | 0.96 | 0.78 | 95th TwrBsMyt | −0.78 | −4.88 | −2.33 | −0.77 | 95th TwrBsMxt | 0.41 | 0.40 | 0.25 | 0.47 | 95th PtfmPitch | 4.41 | 5.40 | 4.44 | 4.41 | 95th PtfmRoll | −0.30 | −0.63 | −0.57 | −0.30 |
|
|