Research Article

An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

Table 2

System performance comparison.

ParameterProposed procedureReference [32]Reference [33]Reference [34]

Linear equation 𝐴 = 0.069 + 0.281C 𝐴 = 0.011 + 0.170 C
Working range (mg L−1)0.02–2.00.6–4.80.05–10.02–14
Linear coefficient ( 𝑅 2)0.9990.9980.9990.998
RSD (%), n = 111.0<2.00.91.4
LOD, 3σ ( 𝜇 g L−1)6.060030510
Determination per hour841511045
Reagent consumption ( 𝜇 g)2.4401501300
Effluent generation ( 𝜇 L)432343013602200

Per determination.