CompoundsCalibration curveR2Linearity range (μg/mL)LOQ (μg/mL)LOD (μg/mL)Recovery (%)RSD (%)

Paeonifloriny = 303x − 3.670.999850–100011.73.51042.1
Chlorogenic acidy = 0.57x − 0.400.99995–1004.61.499.34.4
Rosmarinic acidy = 0.55x − 0.190.99995–1003.71.11002.3
Hyperosidey = 0.71x + 0.180.99995–1004.21.295.32.2
Isoquercitriny = 0.76x + 0.160.99975–1004.71.41051.8
Quercetin-3-O-glucuronosidey = 0.69x − 0.470.99995–1004.41.398.22.7
Salvianolic acid By = 673x − 10.640.999750–10005.81.71012.7
Lithospermic acidy = 0.74x − 0.190.99975–1004.01.21034.4
Astragaliny = 0.88x − 0.540.99965–1004.91.51031.5