Research Article
Optimization of the Shunting Operation Plan at Electric Multiple Units Depots
Table 5
The shunting operation plan generated by CPLEX at the stub-end EMU depot.
| Index | Maintenance | Cleaning | Storage | Track | Section | Dwell time | Track | Section | Dwell time | Track | Section | Dwell time |
| S-EMU-1 | 2 | II | 502–642 | 7 | I | 642–672 | 13 | I | 0–502 | S-EMU-2 | 3 | II | 524–680 | 5 | I | 325–524 | 10 | I | 5–325 | S-EMU-3 | 2 | I | 502–725 | 6 | I | 302–502 | 12 | I | 37–302 | S-EMU-4 | 3 | I | 66–302 | 6 | II | 302–426 | 12 | I | 426–761 | S-EMU-5 | 4 | I | 163–325 | 6 | I | 524–568 | 15 | II | 325–524 | S-EMU-6 | 4 | II | 219–325 | 5 | II | 325–524 | 15 | I | 524–741 | S-EMU-7 | 4 | I | 325–541 | 7 | I | 255–285 | 13 | II | 285–325 | S-EMU-8 | 4 | II | 325–541 | 5 | I | 261–325 | 12 | II | 541–651 | S-EMU-9 | 3 | I | 524–790 | 5 | II | 280–325 | 15 | I | 325–524 | L-EMU-10 | 1 | — | 579–755 | 6 | — | 20–80 | 14 | — | 80–579 | L-EMU-11 | 1 | — | 104–254 | 5 | — | 44–104 | 11 | — | 254–666 | L-EMU-12 | 3 | — | 325–524 | 5 | — | 524–701 | 15 | — | 131–325 | L-EMU-13 | 4 | — | 546–710 | 7 | — | 486–546 | 9 | — | 150–486 | L-EMU-14 | 2 | — | 170–320 | 7 | — | 554–614 | 8 | — | 320–554 | L-EMU-15 | 1 | — | 426–579 | 6 | — | 242–302 | 12 | — | 302–426 | L-EMU-16 | 1 | — | 276–426 | 7 | — | 426–486 | 10 | — | 486–780 | L-EMU-17 | 2 | — | 352–502 | 7 | — | 292–352 | 13 | — | 502–619 |
|
|