Research Article
An Investigation on Cocombustion Behaviors of Hydrothermally Treated Municipal Solid Waste with Coal Using a Drop-Tube Reactor
Table 3
Comparison of , CO, and NO emissions between experimental value and calculated value and the enhancement of the by blending.
| (°C) | (%) | (%) | CO (ppm) | NO (ppm) |
| B1 | a (b) | a | a (b) | a (b) |
| 800 | 94.26 (87.07) | 9.28 | 1954 (3352) | 281 (240) | 900 | 96.34 (90.25) | 7.91 | 2363 (4042) | 370 (342) | 1000 | 97.08 (91.28) | 7.60 | 2333 (3646) | 439 (339) | 1100 | 97.70 (92.71) | 6.66 | 2305 (2963) | 438 (324) |
| B2 | a (b) | a | a (b) | a (b) |
| 800 | 95.69 (84.04) | 10.71 | 1740 (3372) | 246 (225) | 900 | 96.48 (88.30) | 8.05 | 3146 (4243) | 252 (318) | 1000 | 96.81 (89.45) | 7.32 | 2226 (3853) | 384 (333) | 1100 | 96.90 (91.10) | 5.87 | 2038 (3091) | 435 (313) |
|
|
aExperimental value obtained from the measured data.
bCalculated value obtained on the assumption of the compositional ratio of the blends.
|