Research Article
Flash Atomization: A New Concept to Control Combustion Instability in Water-Injected Gas Turbines
Table 1
Test operating points.
| Speed | Test number | Test name | EGT | CDP | Water flow | Temp water | Gas flow | rpm | | | Deg C | KPa | L/hr | Deg C | m3/hr |
| 55000 | 1.1 | Dry 1 | 530 | 55.2 | 0 | 0 | 9.06 | | 1.2 | Wet 1 | 510 | 55.2 | 15.1 | 0 | 9.3 | | 2.1 | Dry 2 | 530 | 55.2 | 0 | 0 | 9.06 | | 2.2 | Wet 2 | 510 | 55.2 | 15.1 | 0 | 9.3 | | 3.1 | Dry 3 | 530 | 55.2 | 0 | 0 | 9.06 | | 3.2 | Wet 3 | 510 | 55.2 | 15.1 | 0 | 9.3 | | 3.3 | Eff. 4 | 510 | 55.2 | 15.1 | 0 | 9.06 | | 4 | Dry 4 | 533 | 55.2 | 0 | 0 | 9.3 | | 5 | Eff. 5 | 509 | 55.2 | 12.1 | 111 | 9.6 | | 6 | Dry 6 | 522 | 55.2 | 0 | 0 | 9.06 | | 7 | Eff. 7 | 513 | 55.2 | 12.1 | 112 | 9.6 | | 8 | Dry 8 | 518 | 55.2 | 0 | 0 | 9.06 | | 9 | Eff. 9 | 509 | 55.2 | 12.1 | 112 | 9.6 |
| 62000 | 10 | 62 dry 10 | 529 | 55.2 | 0 | 0 | 9.9 | | 11 | 62 eff. 11 | 529 | 62 | 9.5 | 120 | 9.9 | | 12 | 62 eff. 12 | 526 | 62 | 13.2 | 120 | 10.2 | | 13 | 62 eff. 13 | 520 | 62 | 13.2 | 105 | 10.2 | | 14 | 62 wet 14 | 514 | 62 | 13.2 | 65 | 10.2 |
|
|