Model parameters for the physical model.

Parameter Value

𝑐 1 3 4 3 m / s
𝑐 2 3 7 4 m / s
𝑅 𝑢 −0.89
𝑅 𝑑 −0.89
𝑇 1 = 𝑇 𝑢 2 9 3 K
𝑇 2 = 𝑇 𝑑 3 4 7 K
𝑇 𝑓 0 . 0 0 3 9 1 s
𝜏 𝑓 0 . 0 0 1 8 s
𝑘 𝑓 918