Research Article

Tin(II) Selective PVC Membrane Electrode Based on Salicylaldehyde Thiosemicarbazone as an Ionophore

Table 2

Composition of PVC membrane of (STSC) and performance characteristics of Sn2+ selective sensors based on them.

S. no.PVCPlasticizerIonophoreExcluder NaTPBSlope (mv/decade)Linear range

12867 (TBP)058.91 × 10−3 to 1 × 10−6
22858 (TBP)8529.21 × 10−2 to 1 × 10−8
32857 (TBP)5535.71 × 10−3 to 1 × 10−7
42859 (TBP)7522.81 × 10−2 to 1 × 10−5
62857 (DOP)5518.31 × 10−3 to 1 × 10−5
72858 (DOP)4533.41 × 10−2 to 1 × 10−4
82859 (DOP)3525.71 × 10−2 to 1 × 10−5