Water inorganic ion analysis method.

ElementMethodReference methodLOD

ChlorideMohr/colorimetric methodASTM D44580.5 mg/L

BasicityPotentiometryASTM D 10671 mg/L

AmmoniaTitrimetryGB/T 7478nitrogen 0.2 mg/L

BariumAtomic absorption methodGB/T 15506
ASTM D 3651
1.7 mg/L

CalciumAtomic absorption method EDTA titrationGB/T 11905 0.02 mg/L
GB/T 74761 mg/L

FerrumAtomic absorption method o-phenanthroline spectrophotometric methodGB/T 11911
ASTM D 1068

MagnesiumAtomic absorption methodGB/T 119050.0005 mg/L

PotassiumAtomic absorption methodGB/T 119040.05 mg/L

SodiumAtomic absorption methodGB/T 119040.02 mg/L

StrontiumAtomic absorption methodSY/T 59820.03 mg/L

SulfideIodometryHJ/T 600.4 mg/L