Research Article

The Influence of Aluminum Tripolyphosphate on the Protective Behavior of an Acrylic Water-Based Paint Applied to Rusty Steels

Table 4

Impedance value of painted samples with scratch calculated from EIS spectra.

0 h8 h24 h96 h192 h

(Ω·cm2)243.5356.7286.4258.9259
of (F·cm−2·s)1.91 × 10−42.10 × 10−41.75 × 10−41.20 × 10−41.04 × 10−4
0.77240.64730.70350.76980.7913
(Ω·cm2)4.83 × 1042.02 × 1042.62 × 1043.30 × 1043.73 × 104