Research Article
Evaluation and Characterization of Plasma Sprayed Cu Slag-Al Composite Coatings on Metal Substrates
Table 1
Operating parameters for coating deposition.
| Parameter | Operating range |
| Operating power | 10–25 kW | Arc current | 400–600 A | Primary Plasmagen gas (argon) flow rate | 40 Lpm | Secondary Plasmagen gas (helium) flow rate | 8 Lpm | Carrier gas (argon) flow rate | 10 Lpm | Nozzle to substrate distance (stand-off distance) | 100 mm |
|
|