Research Article

Automated Design of an FDI System for the Wind Turbine Benchmark

Table 3

Fault signature matrix.

Δ 𝛽 1 Δ 𝛽 2 Δ 𝛽 3 Δ 𝜔 𝑔 Δ 𝜏 𝑔 Δ 𝛽 1 , 𝑚 1 Δ 𝛽 1 , 𝑚 2 Δ 𝛽 2 , 𝑚 1 Δ 𝛽 2 , 𝑚 2 Δ 𝛽 3 , 𝑚 1 Δ 𝛽 3 , 𝑚 2 Δ 𝜔 𝑟 , 𝑚 1 Δ 𝜔 𝑟 , 𝑚 2 Δ 𝜔 𝑔 , 𝑚 1 Δ 𝜔 𝑔 , 𝑚 2

𝐺 1 ( 𝑀 1 ) x x
𝐺 2 ( 𝑀 2 ) x x
𝐺 3 ( 𝑀 3 ) x x
𝐺 4 ( 𝑀 4 ) x x
𝐺 5 ( 𝑀 5 ) x x
𝐺 6 ( 𝑀 8 ) x
𝐺 7 ( 𝑀 1 1 ) x x x
𝐺 8 ( 𝑀 2 7 ) x x
𝐺 9 ( 𝑀 2 9 ) x x
𝐺 1 0 ( 𝑀 3 1 ) x x
𝐺 1 1 ( 𝑀 7 ) x
𝐺 1 2 ( 𝑀 6 ) x
𝐺 1 3 ( 𝑀 1 4 ) x x x
𝐺 1 4 ( 𝑀 2 8 ) x x
𝐺 1 5 ( 𝑀 3 0 ) x x
𝐺 1 6 ( 𝑀 3 2 ) x x