Research Article

Experimental Determination of Heat Transfer Coefficient in Stirred Vessel for Coal-Water Slurry Based on the Taguchi Method

Table 6

Results for quality characteristics and signal-to-noise ratio.

Experiment no.Heat transfer coefficient W/m2 K.S/N ratio (dB)
Reading 1Reading 2Reading 3Mean

1521.86525.47540.09529.1454.47
2615.36626.27625.60622.4155.88
3608.48612.96624.49615.3155.78
4652.78654.89675.12660.9356.40
5624.12629.38640.25631.2556.00
6576.41583.94584.57581.6455.29
7679.83676.14679.80678.5956.63
8630.82634.15640.51635.1656.06
9678.83684.33680.23681.1356.66