Research Article

A Radiative Transfer Modeling Methodology in Gas-Liquid Multiphase Flow Simulations

Table 4

Sensitivity of radiative transfer predictions to the initial bubble diameter.

Model (bubble diameter)Volume averaged incident radiation (W/m2)Incident radiative flux on wall opposite to the radiator (W/m2)Incident radiative flux on the side walls (W/m2)

TFM (1 mm)2153355
TFM (4 mm)2074453
TFM (10 mm)2055650