Test conditions and expected values for the resistor array.

Test conditionConfigurationIdeal value for (AVCC units)

1Gain selection = 10.2500
2Gain selection = 20.5000
3Gain selection = 30.6250
4Gain selection = 40.7500
5Gain selection = 50.8125
6Gain selection = 60.8750
7Gain selection = 70.9375