Minimum operational costs achieved for the different simulation scenarios and respective standard deviation between simulation runs with different initial parameters.

(m)0.300.801.301.80
( /day)MinσMinσMinσMinσ

GA X1,FDS1 pump/613.10.014.00.013.10.014.50.0
2 pump/314.00.313.40.014.61.014.50.8

GA X1,VDS1 pump/612.60.112.50.112.80.113.10.0
2 pump/313.10.312.80.613.80.214.40.1