Research Article
Heat Transfer Analysis of MHD Water Functionalized Carbon Nanotube Flow over a Static/Moving Wedge
Table 3
Comparison of skin friction
when
for a conventional fluid (
).
| | Kuo [45] | Rajagopal et al. [46] | Present results |
| 0 | 0.4696 | 0.4696 | 0.4696 | 0.05 | 0.5317 | 0.5311 | 0.5311 | 0.1 | 0.5879 | 0.5870 | 0.5870 | 0.2 | 0.6876 | 0.6867 | 0.6867 | 0.3 | 0.7755 | 0.7748 | 0.7748 | 0.4 | 0.8549 | 0.8544 | 0.8544 | 0.5 | 0.9279 | 0.9277 | 0.9277 | 0.6 | 0.9958 | 0.9958 | 0.9958 | 0.7 | 1.0594 | — | 1.0598 | 0.8 | 1.1196 | 1.1203 | 1.1203 | 0.9 | 1.1767 | — | 1.1777 | 1 | 1.2313 | 1.2326 | 1.2326 | 2 | 1.6831 | — | 1.6872 |
|
|