Research Article

Protective Sliding Carbon-Based Nanolayers Prepared by Argon or Nitrogen Ion-Beam Assisted Deposition on Ti6Al4V Alloy

Table 1

Peak parameters of the fitted Raman spectra.

SamplePeak 3 (cm−1)Peak 2 (cm−1)Peak 1 (cm−1)Integrated areas ratio (1 + 2)/3

C:Ar1563140211782.43
C:N 1565140711982.67
C 1567139411233.09