Research Article

Electrical Breakdown Properties of Clay-Based LDPE Blends and Nanocomposites

Table 3

Weibull parameters for DC breakdown test of LDPE/clay blends and nanocomposites.

SampleNumber of specimens
(kVmm−1)
95% 
confidence 
intervals
LowerUpper

LDPE847019.87453478
LDPE/1C838710.77361414
LDPE/2.5C843911.23412469
LDPE/5C83669.33338396
LDPE/10C83379.54312364
LDPE/15C829411.16275314
LDPE/SEBS838610.14359415
LSPE/SEBS/5C82767.02248306
LDPE/SEBS-MA838511.55361410
LDPE/SEBS-MA/5C83097.09279343