Research Article

Numerical Simulation and Experimental Analysis of Microstructure of Magnetorheological Fluid

Table 4

Angle between the particle chain and the direction of the magnetic field at different shear strain rates.

The angle between the particle chain and the direction of the magnetic field (°)

Analog value13.124.9
Experimental value12.625.7
Relative error (%)4.0%3.1%