Table 2:
Values of rate constants for reduction and half-life of CT (
,
) with Pd hybrid catalyst and varying hydrogen gas concentrations, [pH
2
].
S. no.
Type of support
H
2
gas [pH
2
] atm
CT transformation rates
(Hr
−1
)
(Hr)
1
Pd/Foam
0.5
0.101
6.86
0.05
0.109
6.35
0
0.003
231.0
2
Pd/CNT/Foam
0.5
0.404
1.71
0.05
0.376
1.84
0
0.015
46.2