Review Article
Clinical Applications of FDG PET and PET/CT in Head and Neck Cancer
Table 2
Studies evaluating the performance of FDG PET for the detection of distant metastases and synchronous 2nd tumor in HNC.
| Author year | Number of patients | Positive PET | True positive (distant mets + 2nd primary) | False positive | Notes |
| Ng et al. [34], 2009 | 111 | 16 | 13/16 | 3/16 | CT/MR detect 4/16 | Chua et al. [35], 2009 | 68 | 6 | 5/6 | 1/6 | CT + BS detect 4/6 | Liu et al. [36], 2007 | 300 | 61 | 50/61 | 11/61 | | Yen et al. [37], 2005 | 118 | 32 | 24/32 | 8/32 | | Goerres et al. [12], 2003 | 34 | 8 | 7/8 | 1/8 | PET modified Treatment in 15% | Sigg et al. [38], 2003 | 58 | 8 | 7/8 | 1/8 | PET modified Treatment in 5% | Schwartz et al. [39], 2003 | 33 | 7 | 7/7 | 0/7 | |
| Total | 722 | 138 | 113/138 | 25/138 | |
|
|