Clinical Study

Macular Retinal Ganglion Cell Complex Thickness and Its Relationship to the Optic Nerve Head Topography in Glaucomatous Eyes with Hemifield Defects

Table 3

Correlations between the mGCC thickness and the HRT-II parameters.

HRT-II parametersDamaged hemisphereIntact hemisphere
RPRP

Disc area0.15.5610.22.378
Cup area−0.35.1520.003.990
Rim area0.58.0130.24.343
Cup area/disc area−0.56.013−0.13.622
Cup volume−0.20.4500.05.857
Rim volume0.64.0040.54.021
Mean cup depth−0.10.6830.26.294
Maximum cup depth0.08.7450.25.310
Height variation contour−0.11.349−0.14.593
Cup shape measure−0.35.1260.16.520
Mean RNFL thickness0.58.0120.66.003
RNFL cross-sectional area0.57.0140.70.001

mGCC = macular ganglion cell complex, HRT-II = Heidelberg Retina Tomograph II, RNFL = retinal nerve fiber layer, .