Corneal Biomechanical Assessment Using Corneal Visualization Scheimpflug Technology in Keratoconic and Normal Eyes

Table 2

Correlation coefficient between DA and tomography parameters and intraocular pressure.

Control groupKC group
r valueP valuer valueP value

Flat keratometry −0.030.8180.4500
Steep keratometry −0.1190.3650.6330

Mean keratometry −0.0740.5730.5450
Astigmatism−0.2320.0750.6080

Central corneal thickness−0.2630.042−0.520

Corneal volume at 3.0 mm−0.2630.042−0.4310.001
Corneal volume at 5.0 mm−0.2620.043−0.2640.041

Corneal volume at 7.0 mm−0.2590.046−0.0650.624
Corneal volume at 10 mm−0.2580.0460.0590.654

Anterior chamber angle0.1660.206−0.0460.727
Anterior chamber depth−0.0030.9830.2110.105

Anterior chamber volume0.0090.9430.0300.823
IOP-GAT −0.7630−0.3950.002

IOP-GAT: intraocular pressure measured by Goldmann applanation tonometry.