Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes

Table 1

Demographics and preoperative biometrics of the study population.

ParameterValue
Plus-power IOLMinus-power IOLZero-diopter IOLAll

Enrolled subjects ()158121171
Eyes ()158121171
Gender, (%):
 Male80 (51%)6 (50%)187 (51%)
 Female78 (49%)6 (50%)84 (49%)
Age (y)
 Mean ± SD57.72 ± 12.6151 ± 154157.65 ± 12.53
 Range20 to 9232 to 8020 to 92
Axial length (mm)
 Mean ± SD28.77 ± 2.1533.81 ± 1.9034.4429.14 ± 2.50
 Range26.01 to 34.6330.20 to 37.3126.01 to 37.31
Anterior chamber depth (mm)
 Mean ± SD3.47 ± 0.393.34 ± 0.473.453.46 ± 0.40
 Range2.34 to 4.172.57 to 5.112.34 to 5.11
Keratometric value (D)
 Mean ± SD43.51 ± 2.1944.62 ± 2.2443.5343.61 ± 2.22
 Range40.36 to 48.0541.95 to 48.1940.36 to 48.19
IOL power (D)
 Mean ± SD9.16 ± 4.24−2.75 ± 1.4208.21 ± 5.28
 Range+1.00 to +20.00−5.00 to −1.00−5.00 to +20.0