Abstract

Confocal Laser Scanning Microscopy (CLSM) has been used as a fast, user-friendly, and noninvasive tool for characterizing the phase composition differences at the substrate and air interfaces in thick films of polymer blends. A clearly different phase composition at the blend/glass interface and at the blend/air interface has been detected. We show that PCBM preferentially accumulates at the glass/blend interface, while P3HT preferentially accumulates at the blend/air interface, by comparing the integrated signal intensity of the luminescence coming from both interfaces. Our results demonstrate that CLSM can be used conveniently for the fast identification of a preferential phase segregation at interfaces in polymer blends. This is useful in the research field on devices (like sensors or planar waveguides) that are based on very thick layers (thickness higher than 1 μm).

1. Introduction

In the last few years, it has been widely demonstrated, using several complex experimental techniques, that many systems composed of organic blends undergo a vertical phase stratification. For instance, polymers blended with fullerenes like poly[(9,9-dioctylfluorenyl-2,7-diyl)-alt-5,5-(40,70-di-2-thienyl-20,10,30-benzothiadiazole)] (APFO-3) [1, 2] where the dynamic secondary ion mass spectroscopy (SIMS) technique has been used for the characterization, or poly[(4,4′-bis(2-ethylhexyl)dithieno[3,2-b:2′,3′-d]silole)-2,6-diyl-alt-(2,1,3-benzothiadiazole)-4,7-diyl] (PSBTBT) [3] using XRD and small-angle Neutron Scattering, or Poly[[9-(1-octylnonyl)-9H-carbazole-2,7-diyl]-2,5-thiophenediyl-2,1,3-benzothiadiazole-4,7-diyl-2,5-thiophenediyl] (PCDTBT) [4] as well as all-polymer blends like poly(9,9-di-n-octylfluorene-alt-benzothiadiazole) (F8BT) and poly(9,9-di-n-octylfluorene-alt-(1,4-phenylene-((4-sec-butylphenyl)imino)-1,4-phenylene)) (TFB) [5]. The vertical stratification of the prototype poly(3-hexylthiophene) (P3HT) blended with -phenyl-C61-butyric acid methyl ester (PCBM) has been characterized by several experimental techniques. Tsoi et al. studied thin films of RR-P3HT : PCBM and RRa-P3HT : PCBM by UV and X-ray photoelectron spectroscopy (UPS and XPS) [6], demonstrating that the P3HT chains are preferentially ordered at the blend-air interface, while PCBM tends to accumulate at the substrate-blend interface. Xue et al. [7] investigated the effect of the annealing process on the vertical stratification of P3HT : PCBM blend by means of X-ray diffraction (XRD) and near-edge X-ray absorption fine structure spectroscopy (NEXAFS). Karagiannidis et al. [8] also studied the annealing effects on the vertical phase rearrangement in P3HT : PCBM thin films by XRD, confirming the accumulation of PCBM on the bottom interface and of P3HT at the top interface. Ellipsometry has been used too by Madsen and coworkers [9] for monitoring the vertical phase separation in P3HT : PCBM blend, finding results compatible with that given by XPS characterization.

Confocal Laser Scanning Microscopy (CLSM) can not attain the spatial resolution proper of the above mentioned techniques (in the nm scale), being limited by the diffraction of light. Moreover, it can not be used for a morphological vertical gradient characterization of very thin films (like the ones usually employed in fields such as Organic Light Emitting Diodes or Polymer Solar Cells [10]). Nevertheless, it is a simple, time-preserving, diffused and user friendly technique to be exploited for a fast and preliminary check of experimental parameters that can be of importance in designing a particular experiment where a very thick (≥1 μm) polymer film is desirable. For instance, the preferential phase segregation at interfaces in polymer blends is a key parameter to be known in order to properly understand and characterize the physics and behavior of organic sensor or planar waveguides where a thick organic layer is employed. For example the ideal thickness of bulk heterojunction organic based photodiodes for image sensing should be ~4 μm in order to drastically reduce the reverse bias dark current [11]. Thick films (~1 μm) are also needed to obtain high illuminance detection from ink-jet printed photosensors based on thick luminescent polymer blends [12]. Since the usual device structure is the diode-like one (where the active layer is sandwiched between two conductor layers), it should be desirable to know if there is a difference in the blend composition at the interfaces in order to choose the proper top and bottom conductive layers, improving the charge injection/extraction by matching the interfaces between the hole (electron) injection/extraction conductive layer with the hole (electron) transporting phase inside the active layer blend. Thick samples are also requested when studying the waveguide-assisted Amplified Spontaneous Emission (ASE) from organic layers composed of luminescent species embedded into polymer inert matrix [13], or lasing effects on thick bilayers [14]. The optical gain in the waveguide is strongly dependent on the thickness of the active layer and on the overlap between the gain media, the pump laser beam, and the electromagnetic field inside the waveguide [1517]. Therefore, it should be desirable to know if there is an accumulation on one side of the sample of the luminescent phase inside the wave-guiding layer for thicknesses in the micrometric range.

Although P3HT : PCBM is a standard system used in the field of organic solar cells, here it has been chosen as a mere testing system for the proposed technique, due to the fact that it is already well known that a thick blend of P3HT : PCBM undergoes a vertical phase segregation during the film deposition process, typically forming a thin fullerene-rich layer at the bottom interface and a polymer-rich layer at the top interface [18]. We point out that we have no intention to extend our findings to solar energy conversion based on organic thin films. Moreover, most of the cited results, related on very thin films, can not be extended by extrapolation to thicker films, for it is known that the phase morphology inside the layer strongly depends on the increasing thickness, up to the micrometric range [19].

The CLSM allows to detect and discriminate the photoluminescence (PL) coming from the substrate/blend and from the blend/air interfaces. Comparing the average PL intensity for each phase at the two interfaces, one can easily and quickly detect if there are component differences at substrate and air interfaces and at what extent, that is the aim of this work.

2. Materials and Methods

2.1. Samples Preparation

Three chlorobenzene solutions of P3HT : PCBM have been realized with different relative component ratio, namely 1 : 2, 1 : 1, and 2 : 1 (in P3HT relative content increasing order), each solution with a total concentration of 25 mg/mL. Highly regioregular P3HT (Sepiolid P200) has been purchased from Rieke Metals and 99.5% purity PCBM has been purchased from SES Research, materials have been used as received. The solutions have been stirred for several days at room condition in dark before using them for the thick films preparation.

Ultrathin microscopy cover glass slides (from Bresser, 22 × 22 mm, certified thickness of 130–170 μm) have been carefully cleaned in an ultrasonic bath sequentially with acetone (10 min), ethanol (10 min), isopropanol (10 min), and distilled water (10 min) and then gently dried by a nitrogen gun. Part of the cleaned slides has been monitored by optical microscopy (40x) in order to check for possible damages due to the cleaning process, no damages have been detected. Few drops of the solutions have been gently placed onto the glass slides inside a Petri dish. The samples were then partly covered in order to protect them from external perturbations. The solutions have been used as stirred for the unfiltered samples realization, while they have been filtered by a PTFE filter (0.45 μm pore size) for the filtered samples. The filtering process allows obtaining samples without macroscopic features that can be easily identified in a photoluminescence map, thus giving the opportunity to test the technique also for very uniform systems. The samples have been left in place few hours until all the solvent was evaporated. All the above operations have been performed at room condition inside a chemical fume hood.

2.2. Photoluminescence

Photoluminescence (PL) spectra have been measured by exciting the samples with a He-Cd laser (325 nm wavelength) filtered by a variable neutral density filter. The PL signal was dispersed by a TRIAX 320 monochromator with a 150 L/mm diffraction grating blazed at 500 nm and detected by a Peltier cooled Si-charge coupled device (CCD). The spectral resolution was ~2 nm.

All the above measurements have been performed at room condition.

2.3. Morphological Characterization

Immediately, after the PL measurements, the samples have been morphologically characterized by Confocal Laser Scanning Microscopy with a Nikon Eclipse C1 inverted confocal microscope. A 40x DIC Plan Apochromat objective (0.95 numerical aperture)—equipped with a manually adjustable correction ring—has been used. The samples have been excited by the 488 nm line of an argon laser and the PL signal has been detected by a couple of photomultipliers (PMTs). The signal was detected simultaneously at 530 ± 20 nm using a bandpass filter and above 770 nm using a high pass filter. Incident excitation power was set to 28 μW measured by a power meter placed on the objective focal plane. Single pixel acquisition time was fixed to 42 μs.

Samples thicknesses have been measured by a Dektak Alpha Step profilometer after all the optical and microscopy experiments, thus preventing any preliminary sample damage and/or manipulation. Multiple scratches have been realized all over the samples and thickness values obtained for each scratch have been then averaged. The mean thickness values are reported in Table 1.

In order to characterize the air/blend interface and the glass/blend interface, the samples have been simply tipped over in between the measurement, carefully placing the sample in such a way that the same region is analyzed on both the surfaces. Anyway, no detectable differences have been revealed repeating the measurements on different regions of the given surface, being the sample morphology and thickness homogeneous. Thus, the “tipping over” is not an intrinsic limitation since image shifts are not correlated with any measurable differences in the results. Objective focus has been checked and adjusted at every measurement. During each CLSM experiment, the air/blend interface and the glass/blend interface have been measured keeping constant all the measurement parameters (PMT gain, incident laser power, magnification, and pixel dwell time).

3. Results and Discussion

3.1. Photoluminescence

Unfiltered Samples. PL spectra of the unfiltered samples are reported in Figure 1, normalized to the film thicknesses. The PL peaks at around 650 nm and 700 nm are typical of the P3HT emission [20], while the band around 550 nm can be attributed to residual PCBM emission due to the intermolecular interactions (absorption and luminescence from charge transfer excited states) between not well separated fullerene clusters [21]. Moreover, there is no evidence of P3HT emission around 550 nm (pure P3HT PL is also reported as a dashed line in Figure 1, scaled down in order to be comparable with the blend signal). We notice that the relative intensity of the peak at 550 nm increases with the PCBM content increase, confirming the previous conclusion.

It is well known that the strong PL quenching in this system is related to the efficient charge transfer from P3HT to PCBM after excitation [22, 23]. The spectral shape of the samples is almost the same irrespective of the relative concentration ratio. As it should be expected, the major P3HT emission quenching effect has been detected in the 1 : 2 sample (almost all the P3HT phase participate to the charge transfer process to the overwhelming PCBM phase), while on the contrary, the P3HT emission is clearly evident in the 2 : 1 sample.

Filtered Samples. PL spectra of filtered samples are reported in Figure 2.

The main feature that is clear from the spectral shape is still the presence of the band around 550 nm with non negligible intensity relative to the P3HT emission, similar to the one of the unfiltered samples, previously assigned to CT emission from PCBM clusters. These results then suggest that some of the PCBM clusters responsible for the emission have dimensions lower than 0.45 μm (the filter pore size). On the other side, the quenching effect appears to be less pronounced (compare the 1 : 2 and 1 : 1 spectra), that could be an indication that the filtering process mainly removed not well dissolved PCBM from the solution. However, the thickness of the 1 : 1 sample in this case is higher, thus, other possible morphological and photophysical effects on the overall PL intensity can not be excluded. However, the main scope of PL measurements here is to give strong support to the following conclusions about the phase origin of the detected signals during the CLSM experiments.

3.2. Confocal Laser Scanning Microscopy

In order to check for possible differences between the sample surfaces (air/blend or glass/blend interfaces) it is necessary that the instrument can section the observed specimen, therefore avoiding optical overlap of signals detected on the two surface planes. According to the Nikon instrument specification and to the general confocal laser microscopy principles [24, 25], the actual calculated total depth of field of the used system is 0.64 μm (microscope pinhole was set to 1.2 Airy Unit). This means that there is no optical overlap between the regions at the two interfaces during the measurements (the optical slices on both sides do not overlap each other when the sample interfaces are on focus).

The collecting filters have been chosen in order to separate the emission from the two material phases. The 530 nm band pass filter allows to collect the emission generating from the PCBM rich phase only since there is no emission of P3HT below ~600 nm (see Figures 1 and 2), while the 770 nm high pass filter should account mainly for the P3HT rich phase emission (the very weak PCBM emission around 700–750 nm [21] is cut off by the filter). The PL counts have been integrated over the whole images for the total signal intensity comparison in the following discussion. The reported confocal images in the following have been processed with a median filter for signal noise removing. No normalization has been performed.

Figure 3 reports the confocal images (collected at 770 nm and above) of the unfiltered samples (the important parameter in this case is the depth of field of 0.640 μm. This means that the microscope can collect without any overlap the light that comes from the focus plane ± a slice of 320 nm thick).

Looking at the confocal images at 770 nm channel (Figure 3), where only the P3HT signal is expected, it is observed that for the 1 : 2 and 1 : 1 sample, the total signal intensity (PL counts integrated over the image area) at the glass/blend interface is lower than that at the air/blend interface, confirming a P3HT-phase preferential distribution on top of the specimen. The 1 : 2 and the 1 : 1 samples show at 530 nm (Figure 4) distinguishable PCBM signal at the glass/blend interface and a very weak signal at the air/blend interface, confirming a preferential arrangement of the PCBM phase on the bottom of the sample.

The averaged signal intensity @770 nm is on the contrary less different between the two interfaces for the (P3HT-richer) 2 : 1 sample, meaning that the P3HT span all over both surfaces. On the contrary, looking to the total PL signal counts at the 530 nm channel (Figure 4(g)), where only PCBM-originating emission is expected, the signal is very low on both surfaces. This indicates that most of the PCBM emission could be absorbed by the overwhelming P3HT phase (see also the very weak PL @530 in Figure 1).

We can exclude a possible degradation of the polymer blend at the air/blend interface (respect to the glass/blend interface) due to oxygen interaction with the materials with potential photooxidation process - influencing the luminescence signal intensity. In fact, the oxygen diffusion constant in the blend is in the range 0.15–1.2 μm2s−1 [2628], that means that oxygen penetrate the whole films studied here in 1-2 seconds up to the glass/blend interface. Thus, possible influences on luminescence should be the same on both surfaces. Moreover, the P3HT emission is not decreased by oxygen exposure in the 700 nm and above spectral region [26]. Furthermore, the ultrathin cover glass slice transmits more than 90% of the visible light (transmission spectrum measured by a Cary Varian 500 spectrophotometer, not shown). We can, therefore, neglect any possible glass effects on the blend absorption of laser pump on both interfaces as well as on the transmitted luminescence. Finally, we ruled out any optical interference since the glass thickness is by far greater than the pump and emission wavelength.

We point out that the phase preferential arrangement at the interfaces is a process driven by the differences in the surface energy between P3HT and PCBM (being the P3HT one smaller than that of PCBM [8]) and by the interaction of the blend with the substrate and the air [29, 30]. Therefore, the possible thickness variation among the samples, in the present range limit greater than 1 μm, does not influence the phase composition at the two interfaces [31]. Moreover, the scope of this work is to provide a fast detection of different phase behavior at the interfaces, not claiming—on the contrary—to provide a tool for a complete vertical gradient segregation, since the layer thickness is too low for a convenient multiple slicing of the system. In our opinion, this is not a limitation if we consider the aim of this work, that is, surface phases characterization. It is possible that multiple stratifications could occur but, taking into account the observations given in the introduction about the dept of field and the optical slice overlap, it appears evident that, even in the case of a multilayered structure, the main contribution to the signal would come from the prevalent phase in the interface subsystem.

In order to investigate the dependence of the phase separation on possible PCBM aggregates/clusters content, we have repeated the experiments on fresh films deposited after filtering the solutions.

Figure 5 reports the confocal images collected at 770 nm (glass/blend interfaces (a), (c), and (e), air/blend interface (b), (d), and (f)).

It is clear that there is a macroscopic micrometer-sized phase separation for all the samples at the glass/blend interface, where the brighter regions (percentage of signal higher than the average is of 33.20%, 41.82%, and 34.62%, respectively, calculated by digital image analysis) should be richer in polymer. On the contrary, no clear macroscopic structures are visible on the air/blend interface, that shows a quite uniform luminescence coming from P3HT all over the surface, with almost no difference among the samples (for all, a coverage higher than 85% over the average signal intensity is calculated). Again, what is to be noted here is the averaged PL counts differences between the two interfaces. The PL intensity at the air/blend interfaces is indeed higher than that at the glass/blend interfaces, implying that there is a majority of P3HT on the top surface.

The confocal images in the PCBM aggregates emission range @530 nm (Figure 6) show again more PCBM PL signal at the glass/blend interface, while the signal at the air/blend interface is definitively lower (see PL counts plot in the same figure). The fullerene phase lies mainly at the bottom of the sample.

From the results on filtered samples, we can conclude that the phase composition at the interfaces does not depend on possible clusters/agglomerates of one of the materials. These results demonstrate that the differences in the phase composition at the two interfaces can be revealed by CLSM by comparing the PL intensity even in fine-mixed samples that do not show any particular big cluster or evident macroscopic features.

Although the presented results are related to a P3HT : PCBM thick film casted on glass, the used technique is generally valid for different thick films. The conclusions are valid even when thinking to a structure geometry in which the upper layer of the substrate is composed, for example, by commonly used materials like PEDOT : PSS or ZnO or when realizing diode-like structures. Indeed, even if it is not possible to directly perform the here reported CLSM experiment comprising such additional layers—because the photoluminescence counts detected at the two interfaces would no more be comparable, since the surface comprising the additional layers would suffer from increased scattering and reduced transmittance—in the limits of the present experiment, the parameter that has a strong influence on the interface morphology is the hydrophilic or hydrophobic nature of the substrates interacting with the blend [29]. It is known that the PCBM tends to accumulate towards hydrophilic substrates [30] as confirmed by our results as the standard glass is hydrophilic. The accumulation would then be even more pronounced if instead of on glass the blend was casted on the high hydrophilic PEDOT : PSS or on the hydrophilic ZnO or (ZnO and can be easily made hydrophilic by simple UV irradiation [32, 33]). Since many blend systems used in the cited application fields are composed by species with different hydrophobic/philic properties and free surface energies, the generality of our reports is evident. All the results cited in the Introduction about the vertical phase stratification have been obtained using experimental techniques and facilities not commonly available and that require a great expertise and time-consuming implementation. Moreover, at this stage (to just know if there is a majority of one phase on one particular interface), it is not mandatory to have a nm scale resolution along the sample plane: the important parameter to be detected is the average content on one surface of one of the materials and not the nm scale fine structure of the blend.

4. Conclusions

The Confocal Laser Scanning Microscopy has been exploited as a common, simple, fast, and user-friendly technique to characterize the phase composition differences at interfaces of polymer blends. A clear difference in the macroscopic phase content at the bottom and at the top of the samples has been detected. The novel idea of this work is to apply the CLSM to thick films in fields where the effects of external interfaces are important.

Even if the results on thick films can not be extended directly on thinner films and consequently to those application that require thin films, these results are certainly useful in the preliminary blend morphology characterization field when the phase content at the interfaces is an important parameter to be considered and the thickness of the layer must be of few micrometers. Using the CLSM instead of other techniques like XRD, XPS, UPS, SIMS, or Neutron Scattering could indeed allow a fast in-lab checking of the influence of mixing ratio, solvent, annealing, and preparation process in a quick few-step experiment. Experiments on different and more interesting systems as well as experiments to compare more precisely the morphology of both phases of various blend systems are actually in progress.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

Dr. Mauro Lomascolo and Dr. Roberto Rella of IMM-CNR of Lecce are kindly acknowledged for providing the photoluminescence experimental setup, the chemical fume hood, and the spectrophotometer. Professor Massimo Di Giulio is kindly acknowledged for providing the profilometer. Sandro Lattante has received financial support from the FP7 ALHsolar project-SP3-People Marie Curie ERG (PERG04-GA-2008-239342). This work has been supported by Regione Puglia through the projects Sens&MicroLAB and SMILE.