Research Article

Removal of False Blood Vessels Using Shape Based Features and Image Inpainting

Table 3

Image wise vessel segmentation results for DRIVE database.

ImagesObserver 1Observer 2
TPRTNRACCTPRTNRACC

186.6096.6595.7586.0997.2496.26
284.4997.6596.3083.0798.3596.81
379.3596.9395.1883.4197.3396.09
479.5498.0696.3680.1798.4896.88
577.9198.1996.2982.8798.5297.25
679.4197.1395.4179.1497.8296.08
778.9297.7296.0086.5597.3996.61
880.7196.2694.9286.3095.9595.31
982.2197.0695.8679.6397.6196.16
1080.1698.0096.5379.5098.7197.34
1180.2597.1195.6083.6797.6396.47
1284.0397.1195.9885.1697.4696.47
1378.5797.5295.6775.4098.3596.03
1486.6397.1895.7487.7896.9596.26
1586.4396.5496.1382.2997.5596.41
1683.3697.5596.2782.1498.0996.73
1783.1996.1395.0487.4396.5295.85
1886.2796.5795.7582.3398.2096.74
1989.6797.3396.6974.6299.1096.67
2088.2396.7796.1477.3698.3096.36
Average82.8097.1696.1482.2497.7896.44