Research Article

Removal of False Blood Vessels Using Shape Based Features and Image Inpainting

Table 4

Image wise vessel segmentation results for STARE database.

ImagesObserver 1Observer 2
TPRTNRACCTPRTNRACC

175.4887.4295.6774.4396.2694.24
274.2696.7095.2081.4793.9493.25
388.0396.2095.7279.4292.8792.09
472.4788.4787.2883.3386.8086.55
576.3295.9794.1975.8395.0092.99
688.4596.2995.7474.0596.4493.88
789.0997.4196.7475.4698.1195.16
888.5197.3896.7269.5298.5194.53
988.7997.7197.0174.6597.7394.90
1085.4796.8795.5964.6497.8092.74
1183.8497.4696.4972.3697.9395.00
1286.9597.8497.0079.2898.6896.43
1384.4098.1396.9171.6399.1495.26
1484.5598.2597.0173.3098.9295.52
1581.2397.1695.7977.4098.1195.51
1666.2498.1694.9060.9198.4292.70
1778.7298.6496.8567.9298.9194.85
1881.3198.6297.7480.5298.1497.05
1986.7997.0796.6280.6696.4495.45
2076.6096.0894.7871.4195.3892.99
Average81.8796.8995.7274.4196.6894.05