Research Article

Organic Membranes for Selectivity Enhancement of Metal Oxide Gas Sensors

Table 7

Change of the absolute humidity in the permeate for the thermoplastic polycondensates PC, PEEK, PES, PET, PEN, PA6, PI, and PEI. The concentrations in the feed and permeate were measured with a digital /RH sensor (HYT221).

MembraneSensor [g/m3] [g/m3] [g/m3] [g/m3]

PCHYT22159,62,24,2
PEEKHYT2214,691,12,2
PESHYT2214,593,16
PETHYT2215,310,10,91,8
PENHYT2214,89,70,10,2
PA6HYT2214,69,11,13,4
PIHYT2214,69,11,32,6
PEIHYT2214,691,32,7