Research Article

Electro-Steering Tapered Fiber-Optic Device with Liquid Crystal Cladding

Table 3

Calculated time response of LC devices.

Liquid crystal deviceAverage response time of LC device for 190 V (ms)
1 (Hz)2 (Hz)5 (Hz)10 (Hz)
OnOffOnOffOnOffOnOff

6CHBTOrthogonal12.87.2311.77.2010.35.177.835.17

E7Orthogonal5.417.674.837.673.963.833.905.43
Parallel2.505.002.333.001.672.331.102.23
Twist5.405.004.175.001.672.171.701.43

Measurement error is below 5%.