Research Article

Component Prediction of Antai Pills Based on One-Dimensional Convolutional Neural Network and Near-Infrared Spectroscopy

Table 2

Comparison of evaluation indices of the 1DCNN model, PLSR model, and SVR model with normal spectra.

AnalyteModelRMSECVRMSEP

Analyte 1PLSR0.93400.55680.94910.5088
SVR0.95200.48160.96670.4117
1DCNN0.96830.33970.98450.2807

Analyte 2PLSR0.90271.00770.89241.0346
SVR0.91370.92090.94210.7591
1DCNN0.97800.49500.94890.7129

Analyte3PLSR0.88340.08830.90560.0758
SVR0.92400.07070.87030.0888
1DCNN0.96590.04690.96630.0453