Research Article
Rapid Quality Assessment of Polygoni Multiflori Radix Based on Near-Infrared Spectroscopy
Table 4
Comparison of quantitative model wavelength selection.
| Ingredients | Method | Wavenumber | LVs | Calibration | Prediction | | RMSEC (%) | RMSECV (%) | | RMSEP (%) | RPD |
| Moisture | None | 2666 | 7 | 0.82 | 0.24 | 0.91 | 0.72 | 0.65 | 1.7 | MCUVE | 84 | 4 | 0.87 | 0.81 | 0.89 | 0.78 | 0.63 | 1.8 | CARS | 68 | 4 | 0.97 | 0.29 | 0.38 | 0.93 | 0.29 | 3.8 | RF | 113 | 4 | 0.96 | 0.30 | 0.41 | 0.93 | 0.30 | 3.7 |
| Stilbene glycosides | None | 2666 | 4 | 0.52 | 0.32 | 0.77 | 0.28 | 0.81 | 1.0 | MCUVE | 126 | 4 | 0.76 | 0.63 | 0.69 | 0.61 | 0.71 | 1.1 | CARS | 108 | 4 | 0.93 | 0.33 | 0.45 | 0.91 | 0.41 | 1.9 | RF | 68 | 4 | 0.89 | 0.32 | 0.49 | 0.87 | 0.63 | 1.2 |
| Anthraquinone glycosides | None | 2666 | 6 | 0.58 | 0.54 | 0.69 | 0.54 | 0.75 | 0.8 | MCUVE | 156 | 4 | 0.74 | 0.53 | 0.47 | 0.74 | 0.45 | 1.3 | CARS | 59 | 5 | 0.92 | 0.31 | 0.45 | 0.89 | 0.44 | 1.4 | RF | 98 | 5 | 0.86 | 0.40 | 0.56 | 0.77 | 0.45 | 1.3 |
|
|
The bold values in the table are the model parameter values under the best wavelength selection, and the bold is for emphasis.
|