Research Article

Rapid Quality Assessment of Polygoni Multiflori Radix Based on Near-Infrared Spectroscopy

Table 4

Comparison of quantitative model wavelength selection.

IngredientsMethodWavenumberLVsCalibrationPrediction
RMSEC (%)RMSECV (%)RMSEP (%)RPD

MoistureNone266670.820.240.910.720.651.7
MCUVE8440.870.810.890.780.631.8
CARS6840.970.290.380.930.293.8
RF11340.960.300.410.930.303.7

Stilbene glycosidesNone266640.520.320.770.280.811.0
MCUVE12640.760.630.690.610.711.1
CARS10840.930.330.450.910.411.9
RF6840.890.320.490.870.631.2

Anthraquinone glycosidesNone266660.580.540.690.540.750.8
MCUVE15640.740.530.470.740.451.3
CARS5950.920.310.450.890.441.4
RF9850.860.400.560.770.451.3

The bold values in the table are the model parameter values under the best wavelength selection, and the bold is for emphasis.