Research Article

Stress-Strain Compression of AA6082-T6 Aluminum Alloy at Room Temperature

Table 3

Experimental results summary.

SpecimenmmNStress
MPa
MPaMPa

1a0.07844525227.70.017500.017350.0176613008.2227.7
1b0.02749714254.20.014640.014530.0147517368.0252.2
2a0.18756542289.10.023800.023520.0240913323.5245.5
2b0.19857570294.40.023410.023130.0236917006.2228.7
3a0.86664384329.20.049570.048340.0508415697.4217.4
3b0.92170400360.00.051160.049850.0525218178.4250.4
4a1.75376888393.10.082450.079050.0860516920.9253.0
4b1.61275526386.20.077990.074950.0812014040.0261.4
5a3.31777916398.40.138200.128650.1487317049.7239.7
5b3.01284035429.70.129960.121520.1392215654.3249.2