Research Article
Thermal Radiation Effects on Hydromagnetic Mixed Convection Flow along a Magnetized Vertical Porous Plate
Table 3
Values of against for , 10.0, and when , , , and against by two methods.
| | | | FDM | Asymptotic | FDM | Asymptotic |
| 0.05 | 0.29162 | 0.29725sm | 0.34621 | 0.34725sm | 0.1 | 0.29321 | 0.29901sm | 0.34935 | 0.34824sm | 0.2 | 0.29636 | 0.29954sm | 0.35558 | 0.35654sm | 0.4 | 0.30251 | 0.30559sm | 0.36789 | 0.36559sm | 0.8 | 0.31429 | 0.31369sm | 0.39189 | 0.39369sm | 1.0 | 0.31992 | — | 0.40360 | — | 3.0 | 0.37116 | — | 0.51618 | — | 4.0 | 0.39612 | — | 0.57401 | — | 5.0 | 0.42193 | — | 0.63503 | — | 6.0 | 0.44887 | 0.44860Lr | 0.69949 | 0.69860Lr | 7.0 | 0.47695 | 0.47170Lr | 0.76723 | 0.76170Lr | 8.0 | 0.50613 | 0.50480Lr | 0.83791 | 0.83480Lr | 9.0 | 0.53636 | 0.53790Lr | 0.91119 | 0.91790Lr | 10.0 | 0.56757 | 0.563100Lr | 0.98672 | 0.98310Lr |
|
|
sm stand for small , where Lr for large .
|