DFS parameters.

Parameter Value

𝐶 1 30.14 μF
𝐶 2 185.6 μF
𝐿 52.28 H
𝑅 1673 Ω
𝑅 0 0 Ω
𝑔 1 −0.801 mS
𝑈 −0.365 mS
𝐸 1. 74 V
𝑑 6 V
𝑇 10 ms