Research Article

Symmetry Methods of Flow and Heat Transfer between Slowly Expanding or Contracting Walls

Table 5

Comparison between analytical and numerical solutions for self-axial velocity at for , .

ā€‰ Analytical method Numerical method Percentage error ( )

1.409157 1.412797 0.257641
1.438678 1.440991 0.160530
1.497718 1.501653 0.262055
1.527238 1.534003 0.440984